วันอาทิตย์ที่ 8 เมษายน พ.ศ. 2555

Cheap Fluke 787 ProcessMeter


Cheap Fluke 787 ProcessMeter


Double Your Power A maintenance and calibration tool that will be at home in every instrumentation technician's tool box, the Fluke 787 ProcessMeterT combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution. Multimeter and Loop Calibrator - all in one! The Fluke 787 was the first tool in the industry to combine a loop calibrator with a DMM, giving process technicians double the power in one tool. Now it's even better. Features: Simultaneous mA and % of scale readout on mA output 25% manual step plus auto step and auto ramp on mA output Clear LCD with backlight; 4,000 counts (30,000 counts for dc current) Min, Max, Average, Hold, Relative modes Externally accessible battery for easy battery changes Specifications Current Measurement Range: 0-1 A Resolution: 1 mA Accuracy: 0.2% + 2 LSD Range: 0-30 mA Resolution: 0.001 mA Accuracy: 0.05% + 2 LSD Current Sourcing Range: 0-20 mA or 4-20 mA Resolution: 0.05% of span Drive Capability: 500 Ω @ 24 mA Frequency: to 19.999 kHz, 0.005% + 1 LSD Continuity: Beeps for resistance Voltage measurement Range: 0-1000 V AC or DC Resolution: 0.1 mV to 1.0 V Accuracy: 0.1% Rdg + 1 LSD (VDC) Resistance measurement: to 40 MΩ, 0.2% + 1 LSD Diode testL 2.4 V shows diode voltage drop Environmental Specifications Operating Temperature: -20° to + 55 ° Storage Temperature: -40°C to 60°C Humidity (Without Condensation): 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C Temperature Coefficient: 0.05 x (specified accuracy) per °C (for temperatures 28°C) Safety Specifications Electrical Safety: Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92 Overvoltage category: IEC 1010-1 CAT III Maximum voltage: 1 25-Percent manual step plus auto step and auto ramp on MA output Simulate DC loop current with .05-Percent accuracy and 1-microamp resolution 1000V overload protection on V, ohms, frequency, and 150V overload protection on mA, backed up by a 440 mA 1000V fuse Runs about 50 hours typical (measurement), 12 hours typical (sourcing 12 mA) on one 9-Volt alkaline battery Clear LCD display with backlight

Visit: Offer Waterford Lismore Reflections 27-Inch Accent Lamp

ไม่มีความคิดเห็น:

แสดงความคิดเห็น